Role of Median Nerve Cross-Sectional Area in the Diagnosis of Carpal Tunnel Syndrome
DOI:
https://doi.org/10.70062/globalhealth.v2i4.242Keywords:
Cross-Sectional Area, Electrodiagnostic Studies, Electrodiagnostic Study, Nerve Conduction Study, Neuromuscular UltrasoundAbstract
Carpal tunnel syndrome (CTS) is the most common chronic neuropathy of the upper limb, characterized by compression of the median nerve within the carpal tunnel. It typically results from repetitive hand movements or trauma and leads to pain, numbness, and weakness, making it a significant occupational health concern. Increased intracarpal pressure causes venous stasis, edema, and ischemic damage, which slow nerve conduction and are detectable through electrodiagnostic (EDX) studies. Recently, ultrasonographic measurement of the median nerve cross-sectional area (CSA) has been proposed as a noninvasive diagnostic option. This study aimed to evaluate the diagnostic accuracy of ultrasound-based CSA measurement compared with EDX findings in CTS patients. The research was conducted at Al-Imamain Al-Kadhimain Medical City in Baghdad from November 2024 to March 2025 and included 100 patients (200 hands). All individuals underwent both EDX and high-resolution ultrasonography using a 5–13 MHz linear probe, with CSA calculated by the direct tracing method. CTS was confirmed in 102 hands (51%). Affected hands demonstrated significantly prolonged distal motor and sensory latencies, reduced amplitudes, and lower conduction velocities (p < 0.001). Mean CSA was significantly larger in CTS hands (13.75 ± 3.95 mm²) than in non-CTS hands (10.15 ± 3.33 mm², p < 0.001). ROC analysis produced an AUC of 0.776 and an optimal cutoff of 11.5 mm² (72% sensitivity, 76% specificity). CSA also increased with CTS severity. Moderate accuracy was observed when differentiating mild from moderate CTS at a 12.5 mm² cutoff, and moderate from severe CTS. In conclusion, median nerve CSA measurement by ultrasound is a reliable, noninvasive, and rapid tool for diagnosing and grading CTS, complementing EDX assessment.
References
Adebayo, P. B., & Mwakabatika, R. E. (2021). F-wave parameters and body mass index in [judul terpotong]. Brain and Behavior, 11(4), e02072. https://doi.org/10.1002/brb3.2072
Alkaphoury, M. G., & Dola, E. F. (2024). Ultrasound and magnetic resonance imaging neurography assessment of diagnostic criteria in patients with [judul terpotong] using electrophysiological tests as gold standard: A prospective study. SAGE Open Medicine, 12, 20503121231218889. https://doi.org/10.1177/20503121231218889
Deniz, F. E., Öksüz, E., Sarikaya, B., Kurt, S., Erkorkmaz, Ü., Ulusoy, H., & Arslan, Ş. (2012). Comparison of the diagnostic utility of electromyography, ultrasonography, computed tomography, and magnetic resonance imaging in idiopathic [judul terpotong] determined by clinical findings. Neurosurgery, 70(3), 610–616. https://doi.org/10.1227/NEU.0b013e318233868f
Ege, F., & Aslanyavrusu, M. (2024). An evaluation of minimal F-wave sensitivity in [judul tidak lengkap]. Cureus, 16(5). https://doi.org/10.7759/cureus.60964
Elnady, B., Rageh, E. M., Ekhouly, T., Fathy, S. M., Alshaar, M., Fouda, E. S., Attar, M., Abdelaal, A. M., El Tantawi, A., Algethami, M. M., & Bong, D. (2019). Diagnostic potential of ultrasound in [judul terpotong] with different etiologies: Correlation of sonographic median nerve measures with electrodiagnostic severity. BMC Musculoskeletal Disorders, 20(1), 634. https://doi.org/10.1186/s12891-019-3010-5
El-Shewi, I. E. H., Tawfeek, A. A., Mohamed, A. A., & Mostafa, M. A. (2024). Role of conventional ultrasound and shear wave elastography of median nerve in diagnosis and differentiation of severity in correlation with electrodiagnostic studies. Egyptian Journal of Radiology and Nuclear Medicine, 55(1), 53. https://doi.org/10.1186/s43055-024-01215-0
Fernández-de-las-Peñas, C., Arias-Buría, J. L., Ortega-Santiago, R., & De-la-Llave-Rincón, A. I. (2020). Understanding central sensitization for advances in management [Version 1; peer review: 3 approved]. F1000Research, 9(F1000 Faculty Rev 605). https://doi.org/10.12688/f1000research.22570.1
Genova, A., Dix, O., Saefan, A., Thakur, M., Hassan, A., & Arguello, M. T. (2020). [Judul artikel tidak tersedia]. Cureus, 12(3).
https://doi.org/ (MOHON judul lengkap)
Gervasio, A., Stelitano, C., Bollani, P., Giardini, A., Vanzetti, E., & Ferrari, M. (2020). Carpal tunnel sonography. Journal of Ultrasound, 23(3), 337–347. https://doi.org/10.1007/s40477-020-00460-z
Gonzalez, N. L., & Hobson-Webb, L. D. (2019). Neuromuscular ultrasound in clinical practice: A review. Clinical Neurophysiology Practice, 4, 148–163. https://doi.org/10.1016/j.cnp.2019.04.006
Grzegorzewski, A., Podgórski, M., Stefańczyk, L., & Wysiadecki, G. (2022). Carpal tunnel syndrome: State-of-the-art review. Folia Morphologica, 81(4), 757–769. https://doi.org/10.5603/FM.a2021.0121
Guggenberger, R., Markovic, D., Eppenberger, P., Chhabra, A., Schiller, A., Nanz, D., Prüssmann, K., & Andreisek, G. (2012). Assessment of median nerve with MR neurography by using diffusion-tensor imaging: Normative and pathologic diffusion values. Radiology, 265(1), 194–203. https://doi.org/10.1148/radiol.12111403
Lindstrom, H., & Ashworth, N. L. (2018). The usefulness of electrodiagnostic studies in the diagnosis and management of neuromuscular disorders. Muscle & Nerve, 58(2), 191–196. https://doi.org/10.1002/mus.26126
Malek, N. (2024). [Judul tidak tersedia: etiopathogenesis, clinical manifestations, diagnostics, options of treatment, results, complications—literature review].
Moschovos, C., Tsivgoulis, G., Kyrozis, A., Ghika, A., Karachalia, P., Voumvourakis, K., & Chroni, E. (2019). The diagnostic accuracy of high-resolution ultrasound in screening for and grading its severity is moderated by age. Clinical Neurophysiology, 130(3), 321–330. https://doi.org/10.1016/j.clinph.2018.12.005
Osiak, K., Mazurek, A., Pękala, P., Koziej, M., Walocha, J. A., & Pasternak, A. (2021). Electrodiagnostic studies in the surgical treatment of [judul terpotong]: A systematic review. Journal of Clinical Medicine, 10(12), 2691. https://doi.org/10.3390/jcm10122691
Preston, D. C., & Shapiro, B. E. (2021). Electromyography and neuromuscular disorders (4th ed.). Clinical-electrophysiologic–ultrasound correlations.
Rana, A. Q., Ghouse, A. T., & Govindarajan, R. (2017). Median neuropathy. In Neurophysiology in clinical practice (pp. 105–115). Springer. https://doi.org/10.1007/978-3-319-39342-1_13
Roll, S. C., Takata, S. C., Yao, B., Kysh, L., & Mack, W. J. (2023). Sonographic reference values for median nerve cross-sectional area: A meta-analysis of data from healthy individuals. Journal of Diagnostic Medical Sonography, 39(5), 492–506. https://doi.org/10.1177/87564793231176009
Savage, N. J., & McKell, J. S. (2024). Sonographic measurement of median nerve cross-sectional area to determine severity of [judul terpotong]: A cautionary tale. Journal of Ultrasound in Medicine, 43(9), 1645–1659. https://doi.org/10.1002/jum.16486
Singla, M., Sharma, M. K., Khurana, D., & Lal, V. (2020). Role of high-frequency ultrasound in diagnosing as compared with conventional nerve conduction studies. Annals of Indian Academy of Neurology, 23(5), 649–655. https://doi.org/10.4103/aian.AIAN_469_19
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Global Health: Journal of Health Sciences, Public Health and Pharmacy

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

