Noise Reduction in Lumbar Sagittal Short Tau Inversion Re-covery (STIR) MRI Images Using a Combination of Wiener Filtering With Contrast Stretching and Unsharp Masking

Authors

  • Wahyu Sartika Dewi Poltekkes Kemenkes Semarang
  • Daniel Kartawiguna Poltekkes Kemenkes Semarang
  • Panji Wibowo Nurcahyo Poltekkes Kemenkes Semarang

DOI:

https://doi.org/10.70062/globalhealth.v2i3.225

Keywords:

Contrast Stretching, Lumbar MRI, Noise Reduction, STIR, Wiener Filter

Abstract

Background: Magnetic Resonance Imaging (MRI) is one of the most important imaging modalities in medicine, especially for diagnosing spinal disorders. The Short Tau Inversion Recovery (STIR) sequence has the advantage of suppressing fat signals, but often produces images with a low Signal-to-Noise Ratio (SNR), so that noise can interfere with diagnostic quality. Therefore, image optimization methods through noise reduction and image quality enhancement techniques are needed. Objective: This study aims to analyze the effectiveness of combining the Wiener Filter with Contrast Stretching and Unsharp Mask in reducing noise and improving the quality of Lumbar Sagittal STIR MRI images. Method: This study used an experimental quantitative approach with lumbar sagittal STIR MRI images as the research object. The research process included applying the Wiener Filter as a noise removal method, then improving the quality with Contrast Stretching and Unsharp Mask. Image quality was evaluated quantitatively using the SNR, CNR, PSNR, and MSE parameters. Results: The application of a combination of Wiener Filter with Contrast Stretching and Unsharp Mask showed an increase in SNR and CNR values compared to before processing, as well as higher PSNR values with lower MSE. This indicates that this combination method is effective in reducing noise while sharpening the anatomical structure details in Lumbar Sagittal STIR MRI images. Conclusion: The combination of Wiener Filter with Contrast Stretching and Unsharp Mask has been proven to improve the quality of Lumbar Sagittal STIR MRI images with significant noise reduction, contrast enhancement, and image sharpness. This method has the potential to be implemented in radiology practice to improve diagnostic accuracy.

References

A’yun, Q. (2020). Reduksi noise citra magnetic resonance imaging (MRI) otak dengan metode median filter dan metode adaptive median filter. Prosiding Seminar Nasional, 1–5.

Aljahdali, S., Azim, G., Zabani, W., Bafaraj, S., Alyami, J., & Abduljabbar, A. (2024). Effectiveness of radiology modalities in diagnosing and characterizing brain disorders. Neurosciences (Riyadh), 29(1), 37–43.

Annisa, A., Latifah, L., & Rusyadi, L. (2021). Improving image quality using filtering weighted median filter techniques on magnetic resonance imaging (MRI) breast images. Advances in Health Sciences Research, 34(AHMS 2020), 60–65. https://doi.org/10.2991/ahsr.k.210127.014

Baruqi, M. S. (2016). Pengaruh perubahan time echo (TE) terhadap nilai contrast-to-noise ratio (CNR) sekuens T2WI TSE sagital pada citra MRI lumbal [Skripsi, Universitas Airlangga].

Baselice, F., Ferraioli, G., Ambrosanio, M., Pascazio, V., & Schirinzi, G. (2018). Enhanced Wiener filter for ultrasound image restoration. Computer Methods and Programs in Biomedicine, 153, 71–81. https://doi.org/10.1016/j.cmpb.2017.10.006

Dahlqvist, J. R., Salim, R., Thomsen, C., & Vissing, J. (2020). A quantitative method to assess muscle edema using short TI inversion recovery MRI. Scientific Reports, 10(1), 1–7. https://doi.org/10.1038/s41598-020-64287-8

Dalto, V. F., Assad, R. L., Lorenzato, M. M., Crema, M. D., Louzada-Junior, P., & Nogueira-Barbosa, M. H. (2020). Com-parison between STIR and T2-weighted SPAIR sequences in the evaluation of inflammatory sacroiliitis: Diagnostic performance and signal-to-noise ratio. Radiologia Brasileira, 53(4), 223–228. https://doi.org/10.1590/0100-3984.2019.0077

Diana Ega Rani. (2016). Optimalisasi number of excitation (NEX) terhadap signal-to-noise ratio (SNR) dan kecepatan waktu scanning pada pemeriksaan MRI [Skripsi, Universitas Airlangga]. Perpustakaan Universitas Airlangga.

Fakhrurreza, M., Wahyuni, S., & Ade Nur Liscyaningrum, I. (2018). Modul magnetic resonance imaging. Program Studi D3 Teknik Radiodiagnostik dan Radioterapi, Fakultas Ilmu Kesehatan, UNISA.

Fritz, R. C., & Steinbach, L. S. (1996). Magnetic resonance imaging of the musculoskeletal system. Clinical Orthopaedics and Related Research, 324(324), 321–339. https://doi.org/10.1097/00003086-199603000-00037

Harris, A. D., Bradham, D. D., Baumgarten, M., Zuckerman, I. H., Fink, J. C., & Perencevich, E. N. (2004). The use and interpretation of quasi-experimental studies in infectious diseases. Clinical Infectious Diseases, 38(11), 1586–1591. https://doi.org/10.1086/420936

Hikmah, E. M., & Juliantara, I. P. E. (2023). Prosedur dan peranan sequence coronal STIR (short tau inversion recovery) pada pemeriksaan hip joint klinis edema. Jurnal Ilmu Kedokteran dan Kesehatan, 10(11), 3220–3227. https://doi.org/10.33024/jikk.v10i11.12250

Huang, S. C., Cheng, F. C., & Chiu, Y. S. (2013). Efficient contrast enhancement using adaptive gamma correction with weighting distribution. IEEE Transactions on Image Processing, 22(3), 1032–1041. https://doi.org/10.1109/TIP.2012.2226047

Hulmansyah, D., & Marido, B. (2025). Prosedur pemeriksaan magnetic resonance imaging lumbal dengan kasus hernia nukleus pulposus. Jurnal Mitra Sehat, 15(2), 886–892.

Hulmansyah, D., Santoso, B., & Budiati, T. A. (2023). Implementation of MRI (magnetic resonance imaging) information system to improve service quality in radiology room Arifin Achmad general hospital. International Journal of Radiology and Diagnostic Imaging, 6(3), 87–92. https://doi.org/10.33545/26644436.2023.v6.i3b.346

Indrati, R., Widyastuti, L. P., Sari, T. P., & Sudiyono, S. (2020). Difference of anatomy information MRI knee joint on variation of time repetition sequences STIR in sagittal slices. Journal of Vocational Health Studies, 4(2), 89–94. https://doi.org/10.20473/jvhs.v4i2.2020.89-94

Kartawiguna, D. (2015). Tomografi resonansi magnetik inti. Yogyakarta: Graha Ilmu.

Kawai, Y., Sumi, M., & Nakamura, T. (2006). Turbo short τ inversion recovery imaging for metastatic node screening in patients with head and neck cancer. American Journal of Neuroradiology, 27(6), 1283–1287.

Khudayer, J. D. S. (2018). Wiener filter based medical image de-noising. International Journal of Science and Engineering Applications, 7(9), 318–323. https://doi.org/10.7753/IJSEA0709.1014

Kim, D. W., Kim, C., Kim, D. H., & Lim, D. H. (2011). Rician nonlocal means denoising for MR images using nonparametric principal component analysis. EURASIP Journal on Image and Video Processing, 2011(1), 1–8. https://doi.org/10.1186/1687-5281-2011-15

Kumar, S., Kumar, P., Gupta, M., & Nagawat, A. K. (2010). Performance comparison of median and Wiener filter in image de-noising. International Journal of Computer Applications, 12(4), 27–31. https://doi.org/10.5120/1664-2241

Mohan, J., Krishnaveni, V., & Guo, Y. (2013). A new neutrosophic approach of Wiener filtering for MRI denoising. Meas-urement Science Review, 13(4), 177–186. https://doi.org/10.2478/msr-2013-0027

Nagy, Z., & Weiskopf, N. (2008). Efficient fat suppression by slice-selection gradient reversal in twice-refocused diffusion encoding. Magnetic Resonance in Medicine, 60(5), 1256–1260. https://doi.org/10.1002/mrm.21746

Nurhikmah. (2022). Perbedaan kualitas citra pada pemeriksaan MRI ankle joint dengan menggunakan coil ankle dan flex coil di instalasi radiologi RS Universitas Hasanuddin Makassar. Humantech: Jurnal Ilmiah Multidisiplin Indonesia, 2(2), 235–248. http://journal.ikopin.ac.id/index.php/humantech/article/view/2795

Priyo, U. (2016). Perbedaan informasi anatomi MRI knee joint [Karya tulis ilmiah].

Rochmayanti, D., Widodo, T. S., & Soesanti, I. (2013). Analisis perubahan parameter number of signals averaged (NSA) terhadap peningkatan SNR dan waktu pencitraan pada MRI. JNTETI, 2(4), 37–45.

Sassack, B. C. J. (2023). Anatomy, back, lumbar spine. National Center for Biotechnology Information. https://www.ncbi.nlm.nih.gov/books/NBK557616/

Surya Saruman, A., & Eka Susilawati, F. (2021). Deteksi pengurangan noise pada citra digital menggunakan metode frequency domain code MATLAB. Konferensi Nasional Ilmu Komputer, 550–560.

Ulbrich, E. J., Sutter, R., Aguiar, R. F., Nittka, M., & Pfirrmann, C. W. (2012). STIR sequence with increased receiver bandwidth of the inversion pulse for reduction of metallic artifacts. American Journal of Roentgenology, 199(6), 735–742. https://doi.org/10.2214/AJR.11.8233

Universitas Diponegoro. (n.d.). Prinsip dasar pencitraan MRI. http://eprints.undip.ac.id/72400/3/BAB_II.pdf

Zhang, X. (2016). Image denoising using local Wiener filter and its method noise. Optik, 127(17), 6821–6828. https://doi.org/10.1016/j.ijleo.2016.05.002

Downloads

Published

2025-09-30

How to Cite

Wahyu Sartika Dewi, Daniel Kartawiguna, & Panji Wibowo Nurcahyo. (2025). Noise Reduction in Lumbar Sagittal Short Tau Inversion Re-covery (STIR) MRI Images Using a Combination of Wiener Filtering With Contrast Stretching and Unsharp Masking. Global Health: Journal of Health Sciences, Public Health and Pharmacy, 2(3), 77–92. https://doi.org/10.70062/globalhealth.v2i3.225